Control device: Built-in controller Product structure: Small volume, large current, simple structure, ATS integrated Features: Fast switching speed, low rate, convenient maintenance, reliable performance

Product Description

Control device: Built-in controller
Product structure: Small volume, large current, simple structure, ATS integrated
Features: Fast switching speed, low rate, convenient maintenance, reliable performance Wiring method: Front of board wiring
Conversion method: Grid to grid, grid to generator, self-switching and self-ting
Product shell frame: 100, 160, 250, 400, 630, 1000 1250, 1600, 2000, 2500, 3200
Product current:   20,32, 40, 63, 80, 100, 125, 160, 200, 25, 250, 315, 400, 500, 630, 800, 100, 1250, 1600, 2000, 2500, 3200A
Product classification: Load type
Product pole number: 3, 4 Product standard: GBTT14048.11-2008 ATS E: PC

1.Product Overview
The dual power automatic transfer switch (A.T.S) is an automatic transfer switch that integrates switch and logic control without the need for an external controller, truly realizing mechatronics integration. It has functions such as voltage detection, frequency detection, electrical and mechanical interlocking, and can achieve automatic, electric remote, and emergency manual control.

Operation is managed by the logic control board using various logic commands to control the operation of the motor and gearbox.          The motor drives the switch spring to store energy, instantly releases the acceleration mechanism, quickly connects and disconnects the circuit or performs circuit conversion, and achieves safe isolation through obvious visible states, greatly improving various electrical and mechanical performance.

The switch is designed with a metal casing, which is compact and sturdy.          The control part is a metal shell, and the switch shell components are made of glass fiber unsaturated polyester resin, which has strong dielectric properties, protective capabilities, and reliable operational safety.

The switch is suitable for automatic switching between the main power supply and the backup power supply of the power supply system, or automatic switching and safety isolation of two load devices.

The switch has a beautiful, novel, simple, small size, and comprehensive functions, making it an ideal choice for different occasions

2.Model and meaning

3.Application of Products

The automatic changeover switch for dual power supplies is mainly used in the power distribution or generator network with an alternating frequency of 0 Hz, a rated voltage of AC400V, a working voltage of 220V, a rated current of 16A to 3200, a system of switching between a main and a standby or mutual standby power source, and the switching of loads between public power and generator sets.

It can also be for infrequent connection and disconnection of circuits and isolation of lines. The products are widely used in the power distribution and automation systems of important power supply places such as firefighting,, banks, and high-rise buildings where power outages are not allowed.

4. Performance and characteristics

Adopting dual-column composite contacts, a horizontal pull-out mechanism, pre-stored in a micro-motor, and microelectronic control technology, it essentially achieves zero arc-over (without an arc extinguishing cover);

Reliable mechanical interlocking electrical interlocking are used, and the operating element uses an independent load disconnector, ensuring safe and reliable operation.

The zero-crossing technology is adopted, which allows zeroing in emergencies (cutting off both power supplies simultaneously), meeting the needs of fire control interlocking.

The load disconnector switching uses a single electric motor drive, ensuring and smooth switching with a fast speed.

The operating motor is only energized momentarily during the execution of load disconnector switching, and no working current is required for steady- operation, resulting in significant energy saving;

The load disconnector is equipped with a mechanical interlocking device, ensuring reliable and independent operation of the main and standby power supplies.

It has clear on-off position indication, padlocking function, etc., and reliably achieves isolation between the power source and the load;

It has good safety performance high degree of automation, high reliability,with standard operation, the service life exceeds 5000 times.

It is designed with electromechanical integration, with accurate, flexible and smooth switching, and adopts advanced international logic control technology with strong anti-interference capability, without interference to the outside; It has three stable working modes: main power, standby power off; main power off, standby power on; both main and standby power off (I-0-II); Easy to install, with the circuit using plug-in terminal connections; Four operating functions: emergency manual operation, electric remote control operation, emergency disconnection operation during automatic control state, and automatic control operation

5. Description of the switch structure

Manual automatic button: Control the power supply of the internal control circuit of the switch. When the button is turned on, the switch can achieve full automatic, forced "0", and remote operation; When the button is turned off, the switch can only be manually operated.

Operating handle: When manually operating with the operating handle, the electrical lock must be turned off first.

Mechanical padlock: a specialized padlock mechanism for maintenance. During maintenance, turn the switch to the "0" position, then pull up the padlock mechanism and lock it. It can prevent any accidents (pulling up the padlock will cut off the internal control power of the switch, the switch cannot automatically operate, and it can also prevent the handle from being put on).

Indicator: Indicates the position of the switch in three states (I, 0, II).

6. Main technical performance parameters

Electrical and mechanical performance of the automatic changeover switch with dual power supply

 

7. Main circuit wiring diagram

8. Isolating Dual Power Supply Automatic Transfer Switch Appearance and Installation Dimensions

Appearance and Installation Dimensions Chart (100~160)

1000~1600 Installation diagram

Installation size table 100~1600

2000~3200 installation diagram

Online Inquiry

+86-18815075141

cn@toagoal.com

+8618815075141

Send Inquiry